A Simple Key For Dp50rb Unveiled
one.two.2 Warning Labels Warning Labels Meaning Be sure to carefully read this guide ahead of use gadget. The next labels are a. Will not place the unit with a sloped surface. Or else the readily available in the event the system device could slide, resulting in particular harm or even the device functions With all the cell malfunction.Greatest 4 times tasking for one particular transmitted beam, resulting in exceptional time resolution and higher body price.
three. Click the higher icon within the monitor (prompts “Update” if you set the cursor on it), the update action is completed, if fails, be sure to send out to R&D Centre. Determine 6-one Main Check Maintenance Display screen 4. Right after update is productive, restart the machine right after electrical power off for making the info successful. HDD Partition ... Web page 91 structured report connected knowledge file and DICOM viewing application Report report template obd.bin OBD info file version.txt Version file Remark Remark file AnatomyImage Anatomical photographs Measurement Measurement library Doppler plan and connected boot configuration major file and plug-ins, remote desktop server Multilanguage string file exe videoplay.
Never use any cables aside from the cables furnished Along with the machine by Mindray. 3. Make use of the cable delivered with this system to attach the printer. Other cables may perhaps result in electric shock. Website page 15: Mechanical Security
Cut off cable ties connecting the leading device within the Exhibit by diagonal chopping pliers, and afterwards pull out the corresponding cable plugs.
Mindray’s new generation of black & white ultrasound method, DP-fifty Qualified, is provided with State-of-the-art imaging systems letting deeper penetration and more quickly image acquisition with greater resolution.
The chapter materials the method to confirm most important purpose and functionality of item. This is only employed for reference, not preventive execution. Perform checking and testing of the component shall be performed by Mindray support engineers as well as person with each other. Page sixty six: Typical Test
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
iZoom™ permits precise viewing of impression from length iWorks™ Protocol can help standardize workflow and minimize Test periods
five.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy Exam Action: Do adjustments as the best way in screening the maximum depth. Document the space by 20mm each phase about the longitudinal targets line utilizing the measurement caliper; Select the worth with the best error (to 20mm), estimate the precision utilizing the system underneath The measurement caliper need to be positioned with the upper fringe of the target, NOTE:... Website page 79 Transverse geometric positioning precision Take a look at Step: Cover the scan surface of the phantom with drinking water or couple gel, Carefully Get in touch with the probe Along with the scan floor Alter the depth, building the transverse targets for being exhibited during the picture. Modify the focus position to generally be posited beside the transverse targets (the typical is not very clear) Regulate parameters like achieve, TGC, building each transverse targets to be Plainly shown. Website page eighty five.5.2.4 Blackout Region Check Move: Deal with the scan surface area on the phantom with h2o or few gel, Carefully Get in touch with the probe With all the scan surface Alter the depth at a lower benefit, and set the main focus at the nearest location to the scan floor. Reduce the worth of parameters like AP, Attain until eventually the background sounds just might be noticed. Page 81: Program Update And Servicing
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Discover much better diagnostic details by prolonged see in the anatomical structure on all linear probes
Functionality Examination five.5.1 Check System Resolution Detection depth Geometric Situation Precision Blackout space examination Record the Examination illustrations or photos five.five.two Check Articles The impression used Here's only for reference, persist with the impression outcome in the true Observe: predicament. Needs: Screen: set the distinction and brightness on the medical application worth (or the default status) Procedure setting: dark home, simulating the medical software ecosystem. Site seventy six In ailment that the transverse resolution testing targets are horizontally displayed, report the negligible distance of two targets which can be Plainly acknowledged. Repeat the Procedure higher than to the transverse resolution tests Dp50rb login targets at other depths. As demonstrated in determine beneath. Axial resolution ... Web page 77 When using the convex probe, preserve the transverse resolution screening targets to NOTE: be displayed near the midline. When utilizing a linear probe with steer function, never activate the steer function when execute the transverse resolution exam. Zoom inside the area wherever the targets Situated if needed. The diameter in the goal level at a certain depth is equal into the transverse resolution with the depth. Webpage 78 five.
Your Resource for further biopsy: enabling changes into the scan line to get much better visibility in the needle, nerves and small vessels, guaranteeing the continuity of all data.
Observe: Be sure that you can pull out and thrust into the IO board sockets vertically when pulling out and assembling the IO board assembly to the position in the deal with. Eliminate panhead screws with washers M3X6 (4) utilized to protected the IO board, after which you could potentially just take out the IO board. Web site 116 Eliminate panhead screws with washers (two M3X6) which happen to be set on the principle device, acquire out the higher baffle and afterwards pull out two cables connecting the most crucial board to the facility module assembly.